H2scan offers solutions to the many issues related to hydrogen sensing technologies and the limitations commonly associated with them. H2scan’s hydrogen specific sensing systems are uniquely able to detect hydrogen against virtually any background gases without false readings or the expensive support equipment typically required.
 |
- Hydrogen-specific, solid state sensors
- No false hydrogen readings
- No risk of saturation in high hydrogen concentrations
- No Cross sensitivities to combustible gases
- 10 year product life expectancy
|
|
|
|
for Safety Systems |
 |
 |
HY-ALERTA™ 500 Handheld Hydrogen Leak Detector
|
|
Key Advantages
Auto re-zero feature - eliminates the need for periodic recalibration
Visual indication of a Hydrogen leak
Range of 15 ppm to 100% Vol gas measurement
Hydrogen specific - no interferences from other gases
|
 Learn More
|

Description
 H2scan recognizes the importance of detecting and locating hydrogen leaks as quickly as possible. H2scan’s HYALERTA ™ 500 Handheld Hydrogen Leak Detector is the industry’s most versatile, portable hydrogen leak detector able to respond to the widest range of hydrogen gas concentrations without the need of any peripheral equipment. The sensor probe has a unique visual LED array that will effectively help navigate to the source of a hydrogen leak where hydrogen gas is produced, used, transported, or stored. With two sensing elements on the same semiconductor die, the HY-ALERTA™ 500 can detect hydrogen leaks as low as 15 ppm and will not saturate or be destroyed when detecting high concentrations of hydrogen up to 100%. The flexible cable allows the sensor probe access to virtually all potential leak sources.
Performance

|
Hydrogen Sensitivity Range:
15 ppm to 100% hydrogen by volume
No peripheral equipment needed Initial Response Time: in seconds Ingress Protection: IP64 capable Field Verification/Calibration Period: 1 year Product Life Expectancy: 10 years
|
Lithium Ion Battery Performance

Operating Time: 10 hours Charge Time: 4 hours maximum with included charger |

Operating Conditions

Operating Temperature Range: 0ºC to 45ºC Storage Temperature Range: -20ºC to 45ºC Calibration Background Gas: Air |
Dimensions

|
Unit Weight: 2.15 lbs, 975 g Total Length: 6.8 in. Total Width: 3.4 in. Depth: 1.4 in. Probe Length: 7.8 in. Probe Tip Diameter: 0.5 in. Probe Handle Diameter: 1.2 in. Coiled Cord Length Retracted: 26in. Coiled Cord Length Extended: 72 in. Coiled Cord Diameter: 0.7 in.
|

Dimensions

|
Unit Weight: 2.15 lbs, 975 g Total Length: 6.8 in. Total Width: 3.4 in. Depth: 1.4 in. Probe Length: 7.8 in. Probe Tip Diameter: 0.5 in. Probe Handle Diameter: 1.2 in. Coiled Cord Length Retracted: 26in. Coiled Cord Length Extended: 72 in. Coiled Cord Diameter: 0.7 in.
|

SALES :
T/F: +52(33)13801272; (33)36201659
T/F: +52(55)24536614
Mail: chemicalinst@axtel.net y ventas-chemicalinst@axtel.net
|